What an underfloor heating installation covers
Electric underfloor heating installation, or under-tile heating, for bathrooms and other tiled rooms:
- the layout of the heating mat or cable over the area to be heated
- the heating mat or cable and the floor sensor, laid by us or by the tiler, and tested once laid and before the tiles go down
- the thermostat on the wall, wired to the heating and the sensor
- the circuit from the switchboard
- testing before and after the floor is tiled, and the certificates
How an underfloor heating job runs
- You send the floor plan of the room and tell us the floor finish, or we visit.
- We mark the heated area on the plan and list the thermostat position, the sensor and the circuit route.
- You confirm the list and the quote, and we agree the dates with you and your tiler or builder.
- The circuit and the thermostat cables go in while the walls are open.
- Once the mat or cable and the sensor are laid, by us or by the tiler, we test them before they are covered.
- After tiling, we test the heating again and connect the thermostat.
- The heating is first turned on as the product's instructions allow, and you receive the certificates.
Planning with the tiler and the floor
- The heated area. Mark where the vanity, bath, shower and any fixed cabinets go; the heating is laid on the open floor around them.
- The order of work. The heating is covered by the tiler's materials, so the floor height and the order of work are agreed with the tiler before the mat goes down.
- The thermostat. Its position is agreed with you at the start, on a wall that is easy to reach, so its cable goes in before the linings.
- The floor sensor. It lets the thermostat read the temperature of the floor, and it goes into the floor with the heating.
- Testing. The heating is tested before it is covered, while any damage can still be put right, and again after tiling.
- The switchboard. The new circuit needs room on the board. If there is none, see switchboard upgrades.
Underfloor heating in bathrooms and kitchens
WorkSafe says RCDs should be installed in damp areas of the home where there are electric fittings, such as bathrooms, laundries and kitchens. An RCD constantly monitors the current on its circuit and shuts off immediately if it senses a loss of current. Heating under a bathroom or kitchen floor is in one of those areas, so its circuit is planned with RCD protection.
Underfloor heating is planned with the rest of a bathroom or kitchen upgrade: see kitchen and bathroom electrical and renovations, both part of our residential electrical work. The circuit and connection for a heat pump are covered under heat pump wiring. We install underfloor heating across Auckland, from the North Shore to South Auckland; the suburbs are on our service area page.
FAQ
When does underfloor heating go in?
When the floor is being tiled. The mat or cable goes down on the prepared floor before the tiles, so it is planned with a new build, a renovation or a re-tile.
Who lays the heating mat?
We do, or the tiler does, depending on the job. Either way we test the mat or cable and the floor sensor before they are covered, test again after tiling, then connect the thermostat and the circuit.
Can I choose the heating product?
Yes. Send its installation instructions with the floor plan; the layout, the circuit and the first switch-on follow them.
Will I get a certificate?
Yes. The new wiring for the heating is fixed wiring work, and WorkSafe and EWRB both say a Certificate of Compliance must be issued for any fixed wiring work.